RedSealTruckExam

💧 Hydraulic Systems

What this topic covers

Block J, Hydraulic Systems: 8 of the 135 questions. RSOS task J-39 (hydraulic systems, including PTO-driven equipment).

These are original practice notes, not documents of the Red Seal program. Inspection values come from the National Safety Code standards in force on January 1, 2027, and jurisdictions may vary. Adjustment, torque and clearance values always come from the vehicle manufacturer's documentation. The rest describes standard methods of the trade.

Principles (J-39)

Safety (J-39)

Service (J-39)

Diagnosis (J-39)

SymptomLikely causeCheck
Foam and pump noiseAir drawn into the suction lineSuction fittings and seals
Loud whine, clear oil, high inlet restrictionCavitationInlet screen, suction hose
Load settles, valve holds with ports cappedLeaking piston sealsCylinder
Pump alone loses flow under pressurePump wearFlow test
Good pump, hot relief valve, low deadhead pressureRelief valve passing oilRelief valve
Quiet pump, zero pressurePump not turningPTO engagement and drive

Calculations

Take the free test · full question bank and mock exams with a subscription

Sample questions (5)

1. In a confined hydraulic circuit, a force applied to the fluid creates pressure. According to Pascal's law, how does that pressure act?

  1. It stays at the point where the force is applied.
  2. It is transmitted equally to all parts of the fluid.
  3. It decreases steadily with the distance from the pump.
  4. It acts mainly along the line of the applied force.

Pascal's law states that pressure applied to a confined fluid is transmitted equally to all parts of that fluid, which is why one pump can drive several actuators. Pressure does not stay at the point of application, does not fall off steadily with the distance from the pump, and is not limited to the direction of the applied force.

2. A compactor hydraulic circuit includes a gas-charged accumulator next to a pressure line that must be disconnected. What must be done first?

  1. The accumulator is discharged by the manufacturer's procedure.
  2. The line is cracked open slowly to let the pressure bleed off.
  3. The pump is run for a short time to recharge the accumulator.
  4. The gas precharge is raised to push the oil out of the circuit.

An accumulator stores oil under pressure even when the engine is off, so it is discharged by the manufacturer's procedure before any line is opened. Cracking a line open can inject oil through the skin, running the pump only restores the stored energy, and raising the precharge leaves the circuit pressurized.

3. A technician cleans the inlet screen of a mobile crane reservoir. Fine metal particles are found in the solvent after washing the screen. What is done next?

  1. The screen is reinstalled and the oil is topped up to the mark.
  2. The relief valve is set higher so the debris passes through it.
  3. The oil is replaced with a lower viscosity grade to flush it.
  4. An oil sample is taken and the source of the wear is traced.

Metal particles on an inlet screen show that a component is wearing, so an oil sample is taken and the source is traced among the pump, motors and cylinders before the system is returned to service. Reinstalling the screen and topping up hides the problem, raising the relief setting adds load to worn parts, and a thinner oil gives them less protection.

4. A technician replaces a return-line filter element on snow removal equipment. What is done before the system is returned to service?

  1. The new element is rinsed in solvent to remove its coating.
  2. Fluid level is checked and the housing is inspected for leaks.
  3. The bypass valve is blocked to force the oil through the element.
  4. The old element is cleaned and installed for a second use.

After a filter change the reservoir level is checked and topped up, then the system is run and the housing is inspected for leaks. A new element is installed as supplied without solvent, a blocked bypass valve lets cold oil build back pressure that can collapse or burst the element, and a used element is replaced, not cleaned for reuse.

5. Used hydraulic oil is drained and the spent filters are removed from a lift gate system. How are they handled?

  1. They are poured into the shop floor drain once the oil settles.
  2. They are mixed with shop coolant waste to be picked up later on.
  3. They are recycled or disposed of under jurisdictional regulations.
  4. They are burned in an open barrel set away from the building.

RSOS sub-task J-39.01 requires consumables to be recycled and disposed of according to jurisdictional regulations. A floor drain sends the oil into the sewer, burning it in a barrel releases its contaminants into the air, and mixing it with coolant waste spoils both waste streams for recycling.

Start free

RedSealTruckExam · Topics · Exam guide · Sample questions