RedSealTruckExam

❄️ Climate Control Systems

What this topic covers

Block I, Climate Control Systems: 7 of the 135 questions, RSOS tasks I-37 (heating and ventilation) and I-38 (air conditioning). These are original practice notes, not materials of the Red Seal program. Inspection values come from the National Safety Code standards in force on January 1, 2027 and may vary by province (jurisdictions may vary); adjustment, torque and clearance values always come from the vehicle manufacturer's documentation; the rest is standard trade practice. Refrigerant handling follows jurisdictional regulations; the Federal Halocarbon Regulations, 2022 apply to federal works and undertakings.

Heating and ventilation service (I-37)

Heater diagnosis (I-37)

SymptomLikely causeCheck
Sweet smell, oily film on glass, damp carpetHeater core leakHeater core
Hot inlet hose, cool outlet hose, strong air flowPlugged heater coreFlow through the core
Both hoses only warm, low engine temperatureThermostat stuck openThermostat
Only high blower speed worksOpen resistorResistor or module

Air conditioning components (I-38)

Pressure diagnosis (I-38)

Refrigerant handling (I-38)

Take the free test · full question bank and mock exams with a subscription

Sample questions (5)

1. A technician must disconnect a heater hose to clean the heater core on a truck that has just come in from a highway run. What is done before the hose clamp is loosened?

  1. Close the heater valve and keep the engine at idle.
  2. Remove the surge tank cap while the coolant is hot.
  3. Let the engine cool and relieve system pressure.
  4. Clamp the hose shut with pliers and run the engine.

Hot coolant under pressure can scald, so the engine is allowed to cool and the pressure is relieved before any hose is opened (RSOS sub-task I-37.01 lists hot coolant as a hazard). Closing the heater valve and idling leaves the system hot and pressurized, and removing the surge tank cap while hot releases scalding coolant. Clamping the hose and running the engine keeps the coolant hot and under pressure.

2. A heater core has been replaced and the cooling system has been refilled. What is done next to confirm the repair?

  1. Warm the engine, bleed the air, then check for leaks and heat.
  2. Close the heater valve and top up the coolant once it is cold.
  3. Reinstall the dash and check for leaks at the next service.
  4. Run the engine at idle for one minute, then shut it off.

After a refill, the engine is brought to operating temperature so the thermostat opens, trapped air is bled out, and the new connections and heater output are checked (RSOS sub-task I-37.03 verifies repairs by sensory observations and temperature testing). Topping up cold with the heater valve closed leaves air trapped in the new core. Waiting for the next service lets a leak or overheating go unnoticed, and a one-minute idle does not open the thermostat or purge the air.

3. The blower motor runs only on its highest speed. The fuse is good, and the motor has good power and ground at its connector on high speed. What is checked next?

  1. The heater control valve for a stuck closed position.
  2. The blower motor bearings for excessive wear.
  3. The cab air filter for a badly plugged element.
  4. The blower resistor block or speed control module.

The resistor block or speed control module drops the voltage for the lower speeds, and the highest speed bypasses it, so an open resistor leaves only high speed (RSOS sub-task I-37.02 lists resistors and modules). A stuck heater valve changes the air temperature, not the blower speeds. Worn bearings and a plugged filter would affect every speed, not only the lower ones.

4. A driver reports that the windshield fogs with an oily film and the cab smells sweet when the heater is on. The passenger-side carpet is damp. What is the most likely cause?

  1. A plugged cab air filter in the air inlet.
  2. A leaking heater core in the heater box.
  3. A failed blower resistor in the blower housing.
  4. A binding blend door actuator in the heater box.

A sweet smell, an oily film on the glass and damp carpet are the signs of coolant leaking from the heater core into the heater box (RSOS sub-task I-37.02 lists a coolant smell and a steaming windshield as symptoms). A plugged filter reduces air flow without adding moisture. A failed resistor changes blower speed only, and a binding blend door actuator affects temperature control, not coolant leakage.

5. The cab has no heat on a cold day. The engine is at operating temperature, the heater valve is open, and air flow from the vents is strong. The inlet heater hose is hot and the outlet hose is cool. What is the most likely cause?

  1. A thermostat stuck in the open position.
  2. A blower motor with a failed winding.
  3. A heater core that is plugged with scale.
  4. A blend door stuck in the cold position.

A hot inlet hose and a cool outlet hose mean little coolant is flowing through the core, so the core is plugged (RSOS sub-task I-37.02 lists no heat as a symptom and flow valves and heater cores as components). A stuck-open thermostat would keep the engine cool and both hoses lukewarm. The air flow is strong, which clears the blower, and a blend door in the cold position would not make the outlet hose cool.

Start free